Steps to view all video input points on Harris HView - connect to multiviewer IP via VNC (Real VNC recomended by Harris), (example:192.168.200.36 is the EIC multiviewer) - send control+alt+delete command to the multiviewer - locate and click task manager button (may be off screen, scroll left/right) - locate the Multiviewer Control Panel window (may be off screen, scroll left/right) - click Stop Multiviewer button - click Explorer button - navigate to c:\Utils\BIST folder (may be off screen, scroll left/right) - launch XenaTest.exe (application window may be off screen, scroll left/right) - click Poll button in XVim area - set source number in Channels area (these are HView inputs, 167 = DSS 1) - click set just below Source number - make sure that Repeat is selected in the box right above Offset in Channels area - click Bring to Left button in XVim area - click Run button next to Video check box in XVim area - check that all inputs display the same image properly ____________________________________________________________________ Steps to close and restor Multiviewer - click stop button next to Video check box in XVim area - click clear botton at the bottom of the Centrio Text application window - click exit - close Windows Tas Manager window (may be off screen, scroll left/right) - close Windows Explorer window (may be off screen, scroll left/right) - click Start Multiviewer button on Multiviewer Control Panel window (may be off screen, scroll left/right) - check Configuration popup window, make sure Load last layout on startup is checked in the LD Processor Options area - check Configuration popup window, make sure that LTC Input Format is set to SMPTE 12M in System Options area - click Apply button if necessary - click Launch Multiviewer button - make sure that the multiviewer overlay display launches properly - close VNC connection to multiviewer