RVON-IO, version 2.2.0 ---------------------- Included Files: --------------- Release Notes: readme.txt Main application: rvonio.bib Boot code: adam2EB.bin Utilities: abortos, applodr, aupdater, cmp, cp, defrag, ftp, info, printenv, rm, setenv, unsetenv Upgrade Procedure ----------------- Normally, a new version of the main application (rvonio.bib) would be installed simply by downloading it from RVONedit. However, it may occassionally be necessary to replace the boot code (adam2EB.bin) and/or the onboard utilities, which requires the use of the RVONFILE utility. New in version 2.2.0 -------------------- Support for the separate CWW key on the KP 32 CLD (65th key) Support for Micron flash type (replacement for Intel part) Requires new adam2EB.bin boot code and utilities to support Micron flash type Did not report GPIO input states correctly in "one keypanel" mode (Fixed) Panels marked as "babbling" would never be allowed to power-up again (Fixed) Send key refresh to intercom even when no keypanel connected. New in version 2.1.6 -------------------- This version includes support for the KP 32 CLD family of keypanels. This version includes support for the RVON-2, and updated telnet command help. New in version 2.1.5 -------------------- If corrupt Ethernet link configuration settings are detected, the card now defaults to auto-negotiate mode. Previously, the card would be forced into 10Mbps, half duplex, but if the switch to which the card is connected was fixed at 100Mbps, full duplex, then the card would not be able to create an Ethernet link. New in version 2.1.4 -------------------- Changed codec initialization for lower noise floor. Make sure there is enough free flash space to download new code image. New in version 2.1.2 -------------------- Support for RVON-16. Improved Ethernet auto-negotiation. New in version 2.0.0 -------------------- DIP 4 resets authentication table to default user names and passwords. Changes to Telnet access rights take place on activation (no reboot required). Unsent changes made via Telnet are aborted after two minutes of inactivity. Sending changes from RVONedit gets "No Sessions" if changes pending via Telnet. Sending device IP info only causes reboot if something actually changes. Added SNMP support. New in version 1.2.0 -------------------- Support for RVONedit. Added device and channel descriptions. Made VAD thresholds settable on a per-channel basis. (Previously, there was one VAD threshold for all channels.) New in version 1.1.0 -------------------- Support for RVON-C. Switch to VxWorks IP Stack from Telogy IP Stack. Don't show red LED if channel is unconfigured. New in version 1.0.1 -------------------- If the RVON-IO DIP switch was changed from Remote mode to Local mode, any channels configured with a destination type of RVON-1 (type 1) would be disabled, and any re-enabling would be ignored after the next reset. Pass-through serial statistics are collected and can be queried using the GUI protocol or displayed from Telnet (show ptstat). New in version 1.0.0 -------------------- Initial release of the RVON-IO firmware. NOTE: Requires RVON-8 V1.2.0 or later, and RVON-1 V1.1.0 or later. NOTE: To configure the RVON-IO IP address using a keypanel, you must have: - KP-32 V2.0.2 or later, (including KP-632, KP-832 and Japanese variants) - KP-812 V1.1.1 or later