[Description] Updated version of the software (MAIN: V3.20 => V3.30) for MSU-1000/1500 is released. Upgrade it as necessary. [Change Points] 1. Live Tone Control function is added. (Paint menu) 2. ARIA function is supported. (Maintenance => Lens menu) ARIA: Automatic Restoration of Illumination Attenuation 3. ON/OFF of HDR Black Clip function are supported. 4. ON/OFF of HDR Black Compression function are supported. 5. MultiFormat menu to new function is supported. - Resolution: UHD is added. - OETF: Hyper Gamma4 is added. 6. The new functions of Converter are supported. - ON/OFF of through mode are supported. (Config => Converter => Mode menu) - Input selection is supported. (MultiFormat menu) 7. Diag information display of FAN NG of CCU is added. 8. Model code is added. 9. 8K Detail is added to Paint menu and Custom Paint menu (Default). (Conventional method (V3.10 or later) needs the registration to the Custom Paint by user.) 1. When performing the camera selection on condition that the page is the second page in MultiFormat menu, the page is backed to the first page. This error is corrected so that the second page is kept. 2. HDR Black Compression is added to Simul Setting, and HDR White Clip (ON/OFF, Level) is deleted. - There is a case that color temperature display (C.Temp) does not appear for some cameras. The error is corrected.