---------------------------------------------------------------------- HDME-7000 HD Digial Multi Effect HZDM-7020 Operating Software V5.57 ReadmeFirst.txt April 3, 2003 Copyright (C) 2003 Sony Corporation. All rights reserved. ---------------------------------------------------------------------- This version is only for HDME-7000 systems with the hardware options to do 24Psf. The software is contained in two zip files for Disk 1 and Disk 2. Please extract the zip files and make two seperate 1.44mb floppy disks. Version Upgrade Procedure Refer to the HDME-7000 installation manual for version upgrade procedure. 1. Outline of HZDM-7010/7020 software changes 1.1 Newly supported functions No functions of the V5.57 are newly supported in comparison to the V5.00. 1.2 Fixed bugs 1 GLBL KF Insert cannot be performed 2 System hangs up if a control such as Offset of Pageturn or Volume of Angle etc is adjusted (turned) roughly 3 COMM Busy Error occurs 4 System hangs up with Non Linear effect, Cylinder effect, or Swirl effect 5 Saving/loading KF/SS of HDME from the switcher panel results in Comm Error 0, hanging up the system 6 When system is left in DME-WIPE mode, DME terminates the mode of itself 7 CH copy cannot be performed from the switcher panel The latest version is required on HDS side 8 KF Auto Save cannot be turned off 9 When Modify Mask or PTNNO. 24, 26, 27 is shifted to the right side, a folded noise appears from the left side 10 KF XPT Hold does not work (In/Out menu only) 11 With Pageturn, offset set to –100, a false image appears when angle is turned 12 When HDME is controlled from HDS-7000 control panel, CH cannot be assigned (GLBL is not assigned on switcher panel) 13 Graphic does not appear when Reduce is set to ON because default values for Page202, Graphic, and Reduce Size are set to 0 Default values are corrected 14 When different Screen Sizes are set for CH1 and CH2, Border width becomes unbalanced 15 When MOD is performed with Target size set to 0 by trackball after KF is created, a screen suddenly expands to a full size. (KF, too) 16 When Rotation is repeatedly performed with different XPT NO. at Front/Back, it goes to a different XPT NO. (It often goes to NO. 0) 17 Stop Next KF does not work from GPI 18 Corners are not rounded at Default setting of DME Wipe, Pageturn 19 In Film mode with Vol. set to 100, an abnormal picture appears when Film is set to ON while Film is turned ON/OFF 20 Auto Cube does not work Menu is deleted 21 In 16:9 mode, a dusty noise appears at top and bottom of the cylinder 22 When Multi Move + Non-Linear effect are used at the same time, a dusty noise of one line appears at bottom edge of the screen 23 A folded image appears with DME Wipe PTN NO.1102-1105 1.3 Restrictions [1]CH2 Key-B input cannot be used 1.4 Compatibility with Former Version Key frames and snapshots created by the V5.00 software basically work on the new version, however, may not be always complete.