Example
The following is an example session taken from an SC4 test shell.
Sash command shell (version 1.1.1)
/>
/> test
test>getpid 71
Panel 71 ID: DEMOROOM-XY UCP-XY
test>setpid 71 NEWNAME-XY UCP-XY
test> getpid 71
Panel 71 ID: NEWNAME-XY UCP-XY
test/>exit
/>
If you have already created panels offline using the “Add New Device” section within this guide, you would have already created a name for that panel. This panel will have a red box around it until the created name matches the assigned name given the panel through the SC4 test utility. In this case, use the same steps above, making sure to type the name in the setpid section exactly as it was created in U-CON V4. Simply cycle the power after it has been named. When the network finds the panel, the red box will disappear.
For all CSP style of control panels (coax party line cable) you will use the same format as above (for naming panels) with the exception that the commands are getplpid and setplpid. The list for allowable panel types are:
In the event that you are unable to name a panel using this procedure, or if you have named it and the panel is still not recognized by UCON, showing up in the Active Device List, then call Utah Scientific customer service for help.