Tie Line Properties
The Maximum Tielines Property will update automatically to display the number of tielines configured within the system. The Maximum Search Property will typically be (1). A value higher than 1 will enable the system to connect levels that are not directly connected together. For example, in a system containing a pool converting analog video to SD, and another pool upconverting SD to HD, connections will be enabled between analog video and HD if the Max search is set to 2. For efficiency, use the smallest number possible for the desired number of conversions.