# # Utah Scientific MXLATOR Configuration Data # # [CONFIG_DEFINITION_DATA_START] [FLASH_VERSION_DATA_START] # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # FILE_FORMAT_MX: @00.01 # CUSTOMER_NAME: @xxxxxxxxxxxxxxxxxxxx # SYSTEM_NAME: @xxxxxxxxxxxxxxxxxxxx # FILE_DATE: @MM/DD/YYYY # FILE_REVISION: @?? FILE_FORMAT_MX: @01.04 CUSTOMER_NAME: @USI-DEFAULT SYSTEM_NAME: @DEFAULT FILE_DATE: @10/30/2006 FILE_REVISION: @01 [MX_BUS_DATA_START] # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # # # # The purpose of this section is to provide readback information to the SC-4 controller for # # ALL non-MX routers on the system. Therefore, keep the output numbers in blocks of 16 # # MX level number cannot be duplicated (within each section) # # # ENABLED: @TRUE or FALSE # READ_BACK_STATUS: @0 or 1 or STATUS # READ_BACK: @ # DISCONNECT_INPUT: @ # LEVEL_MAPPING: @,, ENABLED: @FALSE READ_BACK_STATUS: @1 READ_BACK: @0x0060 DISCONNECT_INPUT: @30 LEVEL_MAPPING: @0, 0, 144 LEVEL_MAPPING: @1, 0, 144 LEVEL_MAPPING: @2, 0, 144 LEVEL_MAPPING: @3, 0, 144 LEVEL_MAPPING: @4, 0, 144 LEVEL_MAPPING: @5, 0, 144 LEVEL_MAPPING: @6, 0, 144 [SC_BUS_DATA_START] # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # # # # Input and Output offsets are simply added to the incoming I/O values from the MX bus # # MX level number cannot be duplicated (within each section) # # # # ENABLED: @TRUE or FALSE # MX_SC_MAPPING: @,,,,, # REFRESH_LEVEL: @ # REFRESH_DECADE: @ # USI_SOURCE: @ ENABLED: @FALSE MX_SC_MAPPING: @4, 0, 0, 144, 0, 0 MX_SC_MAPPING: @5, 1, 0, 144, 0, 0 MX_SC_MAPPING: @6, 2, 0, 144, 0, 0 REFRESH_LEVEL: @0 REFRESH_LEVEL: @1 REFRESH_LEVEL: @2 REFRESH_DECADE: @0 REFRESH_DECADE: @1 REFRESH_DECADE: @2 REFRESH_DECADE: @3 REFRESH_DECADE: @4 REFRESH_DECADE: @5 REFRESH_DECADE: @6 REFRESH_DECADE: @7 REFRESH_DECADE: @8 REFRESH_DECADE: @9 REFRESH_DECADE: @10 REFRESH_DECADE: @11 REFRESH_DECADE: @12 REFRESH_DECADE: @13 REFRESH_DECADE: @14 USI_SOURCE: @MX [DB_BUS_DATA_START] # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # # # # Input and Output offsets are simply added to the incoming I/O values from the MX bus # # MX level number cannot be duplicated (within each section) # # # # ENABLED: @TRUE or FALSE # 320_OUTPUTS: @TRUE or FALSE *TRUE = 7 levels 320 outputs / FALSE = 8 levels 160 outputs # 25_DATA_BITS: @TRUE or FALSE *TRUE = 25 bit data bus / FALSE = 24 bit data bus(old stuff) # MX_DB_MAPPING: @,,,,, # REFRESH_LEVEL: @ # REFRESH_DECADE: @ # USI_SOURCE: @ ENABLED: @FALSE 320_OUTPUTS: @TRUE 25_DATA_BITS: @FALSE MX_DB_MAPPING: @0, 0, 0, 144, 0, 0 MX_DB_MAPPING: @1, 1, 0, 144, 0, 0 MX_DB_MAPPING: @2, 2, 0, 144, 0, 0 REFRESH_LEVEL: @0 REFRESH_LEVEL: @1 REFRESH_LEVEL: @2 REFRESH_DECADE: @0 REFRESH_DECADE: @1 REFRESH_DECADE: @2 REFRESH_DECADE: @3 REFRESH_DECADE: @4 REFRESH_DECADE: @5 REFRESH_DECADE: @6 REFRESH_DECADE: @7 REFRESH_DECADE: @8 REFRESH_DECADE: @9 REFRESH_DECADE: @10 REFRESH_DECADE: @11 REFRESH_DECADE: @12 REFRESH_DECADE: @13 REFRESH_DECADE: @14 USI_SOURCE: @MX [ESBC_BUS_DATA_START] #NOTE! Up to 6 es bus control routers can be defined(limited by serial ports used). Simply duplicate the ESBC_BUS_DATA_START section 6 times # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # # Most ES-BUS applications require both serial port types and mapping types to be configured, along with the RCP3_BUS_DATA_START # # SERIAL_PORT is logical and SERIAL_PORT_TR is physical (used for pathfinding) # # The MX_ESBC_LCL_MAPPING applies to the SERIAL_PORT_TR # # The MX_ESBC_MAPPING applies to the SERIAL_PORT # # # # ENABLED: @TRUE or FALSE # SERIAL_PORT: @,,,,, # SERIAL_PORT_TR: @,,,,, # *parity can only be (O)dd, (E)ven, or (N)one # *flowcontrol can only be (N) none, (H) Hardware RTSCTS (9600,8,1,O,N is default) # MX_ESBC_MAPPING: @,,,,,, # MX_ESBC_LCL_MAPPING: @,,,,,, # USI_SOURCE: @ # # # # ES Bus configuration options: # # There are three interface applications # # ESTRC This will simply confirm for the ES protocol (ES TRIB). # # Useful if confirm all is not desirable on ES controllers # # ESTR This will allow ES devices to control a USI router (ES TRIB). # # The non-USI controller must perform all confirms/refreshes. # # ESBC This is the bridge application between USI and ES devices. # # ESBC will bridge for a ES physical router present. # # ESBC LCL will bridge for a USI physical router present. (requires two serial ports) # # ESBCM This is the BusControl Master, USI controls an ES devices. No ES control # # ENABLED: @FALSE SERIAL_PORT: @2, 38400, 8, 1, O, N MX_ESBC_MAPPING: @3, 1, 0, 100, 0, 0 MX_ESBC_MAPPING: @4, 2, 200, 10, -5, 57 USI_SOURCE: @MX [ESBC_BUS_DATA_START] #NOTE! Up to 6 es bus control routers can be defined(limited by serial ports used). Simply duplicate the ESBC_BUS_DATA_START section 6 times # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # # Most ES-BUS applications require both serial port types and mapping types to be configured, along with the RCP3_BUS_DATA_START # # SERIAL_PORT is logical and SERIAL_PORT_TR is physical (used for pathfinding) # # The MX_ESBC_LCL_MAPPING applies to the SERIAL_PORT_TR # # The MX_ESBC_MAPPING applies to the SERIAL_PORT # # # # ENABLED: @TRUE or FALSE # SERIAL_PORT: @,,,,, # SERIAL_PORT_TR: @,,,,, # *parity can only be (O)dd, (E)ven, or (N)one # *flowcontrol can only be (N) none, (H) Hardware RTSCTS (9600,8,1,O,N is default) # MX_ESBC_MAPPING: @,,,,,, # MX_ESBC_LCL_MAPPING: @,,,,,, # USI_SOURCE: @ # # # # ES Bus configuration options: # # There are three interface applications # # ESTRC This will simply confirm for the ES protocol (ES TRIB). # # Useful if confirm all is not desirable on ES controllers # # ESTR This will allow ES devices to control a USI router (ES TRIB). # # The non-USI controller must perform all confirms/refreshes. # # ESBC This is the bridge application between USI and ES devices. # # ESBC will bridge for a ES physical router present. # # ESBC LCL will bridge for a USI physical router present. (requires two serial ports) # # ESBCM This is the BusControl Master, USI controls an ES devices. No ES control # # ENABLED: @FALSE SERIAL_PORT: @1, 38400, 8, 1, O, N SERIAL_PORT_TR: @6, 38400, 8, 1, O, N MX_ESBC_LCL_MAPPING: @3, 1, 0, 144, 0, 0 USI_SOURCE: @MX [ESBCM_BUS_DATA_START] #NOTE! Up to 6 es bus control routers can be defined(limited by serial ports used). Simply duplicate the ESBCM_BUS_DATA_START section 6 times # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # # Most ES-BUS applications require both serial port types and mapping types to be configured, along with the RCP3_BUS_DATA_START # # SERIAL_PORT is logical and SERIAL_PORT_TR is physical (used for pathfinding) # # The MX_ESBCM_LCL_MAPPING applies to the SERIAL_PORT_TR # # The MX_ESBCM_MAPPING applies to the SERIAL_PORT # # # # ENABLED: @TRUE or FALSE # SERIAL_PORT: @,,,,, # *parity can only be (O)dd, (E)ven, or (N)one # *flowcontrol can only be (N) none, (H) Hardware RTSCTS (9600,8,1,O,N is default) # MX_ESBCM_MAPPING: @,,,,,, # USI_SOURCE: @ # # # # ES Bus configuration options: # # There are three interface applications # # ESTRC This will simply confirm for the ES protocol (ES TRIB). # # Useful if confirm all is not desirable on ES controllers # # ESTR This will allow ES devices to control a USI router (ES TRIB). # # The non-USI controller must perform all confirms/refreshes. # # ESBC This is the bridge application between USI and ES devices. # # ESBC will bridge for an ES physical router present. # # ESBC LCL will bridge for a USI physical router present. (requires two serial ports) # # ESBCM This is the BusControl Master, USI controls an ES devices. No ES control # # ENABLED: @FALSE USI_SOURCE: @MX [ESTRC_BUS_DATA_START] # # # # This section will rarely be used. Most applications ENABLED: will be set to FALSE # # #NOTE! Up to 6 estrc bus control routers can be defined(limited by serial ports used). Simply duplicate the ESTRC_BUS_DATA_START section 6 times # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # ENABLED: @TRUE or FALSE # SERIAL_PORT: @,,,,, # *parity can only be (O)dd, (E)ven, or (N)one (Odd is default) # *flowcontrol can only be (N) none, (H) Hardware RTSCTS (None is default) # # # # ES Bus configuration options: # # There are three interface applications # # ESTRC This will simply confirm for the ES protocol (ES TRIB). # # Useful if confirm all is not desirable on ES controllers # # ESTR This will allow ES devices to control a USI router (ES TRIB). # # The non-USI controller must perform all confirms/refreshes. # # ESBC This is the bridge application between USI and ES devices. # # ESBC will bridge for a ES physical router present. # # ESBC LCL will bridge for a USI physical router present. (requires two serial ports) # # ESBCM This is the BusControl Master, USI controls an ES devices. No ES control # # ENABLED: @FALSE SERIAL_PORT: @6, 38400, 8, 1, O , N [ESTR_BUS_DATA_START] #NOTE! Up to 6 es bus control routers can be defined(limited by serial ports used). Simply duplicate the ESTR_BUS_DATA_START section 6 times # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # # # # ENABLED: @TRUE or FALSE # SERIAL_PORT: @,,,,, # *parity can only be (O)dd, (E)ven, or (N)one # *flowcontrol can only be (N) none, (H) Hardware RTSCTS (9600,8,1,O,N is default) # MX_ESTR_MAPPING: @,,,,, # USI_SOURCE: @ # # # # ES Bus configuration options: # # There are three interface applications # # ESTRC This will simply confirm for the ES protocol (ES TRIB). # # Useful if confirm all is not desirable on ES controllers # # ESTR This will allow ES devices to control a USI router (ES TRIB). # # The non-USI controller must perform all confirms/refreshes. # # ESBC This is the bridge application between USI and ES devices. # # ESBC will bridge for a ES physical router present. # # ESBC LCL will bridge for a USI physical router present. (requires two serial ports) # # ESBCM This is the BusControl Master, USI controls an ES devices. No ES control # # ENABLED: @FALSE SERIAL_PORT: @6, 38400, 8, 1, O, N MX_ESTR_MAPPING: @3, 1, 0, 144, 0, 0 USI_SOURCE: @MX [RCP3_BUS_DATA_START] # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # ENABLED: @TRUE or FALSE # IP: @ * this is the IP of the USI controller (SC4 or other) ENABLED: @FALSE IP: @192.168.005.230 REFRESH_TIME: @150 REFRESH_BLOCK: @3 [PROSAN_BUS_DATA_START] #NOTE! Up to 6 Prosan bus control routers can be defined(limited by serial ports used). Simply duplicate the PROSAN_BUS_DATA_START section 6 times # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # ENABLED: @TRUE or FALSE # SERIAL_PORT: @,,,,, # *parity can only be (O)dd, (E)ven, or (N)one (Odd is default) # *flowcontrol can only be (N) none, (H) Hardware RTSCTS (None is default) # NUMBER_FORMAT: @<2 or 3> *number of input or output digits supported in protocol # MX_PROSAN_MAPPING: @,,,,, # USI_SOURCE: @ # #NOTE! The prosan router has levels 'A' thru 'H' # The prosan router input/output 1 is the first bus (MX uses 0 as the first bus) # The input/output offset must map the 0 and 1 relative offset. The offset will almost always be odd # The following will map the first input, output and level of Prosan to the first input, output and level of MX # MX_PROSAN_MAPPING: 0,A,0,64,1,1 # ENABLED: @FALSE SERIAL_PORT: @1, 9600, 8, 1, O , N NUMBER_FORMAT: @2 MX_PROSAN_MAPPING: @3, G, 0, 64, 1, 1 USI_SOURCE: @MX [DATATEK_BUS_DATA_START] #NOTE! Up to 6 Datatek bus control routers can be defined(limited by serial ports used). Simply duplicate the DATATEK_BUS_DATA_START section 6 times # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # ENABLED: @TRUE or FALSE # SERIAL_PORT: @,,,,, # *parity can only be (O)dd, (E)ven, or (N)one (Odd is default) # *flowcontrol can only be (N) none, (H) Hardware RTSCTS (None is default) # MX_DATATEK_MAPPING: @,,,,, # USI_SOURCE: @ # ENABLED: @FALSE SERIAL_PORT: @2, 9600, 8, 1, O , N MX_DATATEK_MAPPING: @0, 0, 0, 250, 0, 0 MX_DATATEK_MAPPING: @1, 1, 0, 250, 0, 0 MX_DATATEK_MAPPING: @2, 2, 0, 250, 0, 0 MX_DATATEK_MAPPING: @3, 3, 0, 250, 0, 0 USI_SOURCE: @MX [DATATEKBC_BUS_DATA_START] #NOTE! Up to 6 Datatek bus control routers can be defined(limited by serial ports used). Simply duplicate the DATATEKBC_BUS_DATA_START section 6 times # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # ENABLED: @TRUE or FALSE # SERIAL_PORT: @,,,,, # *parity can only be (O)dd, (E)ven, or (N)one (Odd is default) # *flowcontrol can only be (N) none, (H) Hardware RTSCTS (None is default) # MX_DATATEK_MAPPING: @,,,,,|,| # MX_DATATEK_LCL_MAPPING: @,,,,,|,| # USI_SOURCE: @ # # The MX_DATATEK_MAPPING mapping is for physical routers on the Datatek system. # The unknown source is sent to the USI as status for MX_DATATEK_MAPPING. # The MX_DATATEK_LCL_MAPPING mapping is for physical routers on the USI system. # The unknown source is sent to the Datatek as status for MX_DATATEK_LCL_MAPPING. # ENABLED: @FALSE SERIAL_PORT: @3, 9600, 8, 1, O , N MX_DATATEK_MAPPING: @0, 0, 0, 250, 0, 0 MX_DATATEK_MAPPING: @1, 1, 0, 250, 0, 0 MX_DATATEK_MAPPING: @2, 2, 0, 250, 0, 0 MX_DATATEK_MAPPING: @3, 3, 0, 250, 0, 0 USI_SOURCE: @MX [SIERRA_BUS_DATA_START] #NOTE! Up to 6 SIERRA bus control routers can be defined(limited by serial ports used). Simply duplicate the SIERRA_BUS_DATA_START section 6 times # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # ENABLED: @TRUE or FALSE # SERIAL_PORT: @,,,,, # *parity can only be (O)dd, (E)ven, or (N)one # *flowcontrol can only be (N) none, (H) Hardware RTSCTS (9600,8,1,O,N is default) # COMMAND_START_CHARS: @TRUE or FALSE True put 2 start characters False put 1 start character. Use TRUE # MX_SIERRA_MAPPING: @,,,,, # USI_SOURCE: @ # # NOTE! Sierra is 1 relative, USI is 0 relative, offsets will be an odd number.> # ENABLED: @FALSE SERIAL_PORT: @2, 9600, 8, 1, O , N COMMAND_START_CHARS: @TRUE MX_SIERRA_MAPPING: @0, 0, 0, 250, 0, 0 USI_SOURCE: @MX [PROBELNS_BUS_DATA_START] #NOTE! Up to 6 Probel Network Slave routers can be defined. Simply duplicate the PROBELNS_BUS_DATA_START section 6 times # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # ENABLED: @TRUE or FALSE # IP_PORT_PROTOCOL: @ Start port for levels. # IP_PORT_ERRORS: @ Port number for UDP error port. # DEFAULT_SOURCE: @ Source used for status when status not known. # MX_PROBEL_MAPPING: @,,,,, # #NOTE! The Probel router is 0 relative on levels/sources/destination so is USI # The USI numbers go only over RCPx, this means they are index's # This does not use the MX bus, no MX connection or configuration required. # Only level 0 on Probel will work. # ENABLED: @FALSE IP_PORT_PROTOCOL: @2000 IP_PORT_ERRORS: @2002 DEFAULT_SOURCE: @100 MX_PROBEL_MAPPING: @0, 0, 0, 250, 0, 0 [PROBELSM_BUS_DATA_START] #NOTE! Up to 6 Probel Serial Master routers can be defined. Simply duplicate the PROBELSM_BUS_DATA_START section 6 times # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # ENABLED: @TRUE or FALSE # SERIAL_PORT: @,,,,, # *parity can only be (O)dd, (E)ven, or (N)one # *flowcontrol can only be (N) none, (H) Hardware RTSCTS (9600,8,1,O,N is default) # USI_SOURCE: @ # MX_PROBEL_MAPPING: @,,,, # #NOTE! The Probel router is 0 relative on levels/sources/destination so is USI # The Probel serial is one level per serial port. # ENABLED: @FALSE [PESASM_BUS_DATA_START] #NOTE! Up to 6 Pesa Serial Master routers can be defined. Simply duplicate the PESASM_BUS_DATA_START section 6 times # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # ENABLED: @TRUE or FALSE # SERIAL_PORT: @,,,,, # *parity can only be (O)dd, (E)ven, or (N)one # *flowcontrol can only be (N) none, (H) Hardware RTSCTS # USI_SOURCE: @ # MX_PESA_MAPPING: @,,,,, # PESA_LEVEL_COUNT: @ # # NOTE! Pesa is 1 relative, USI is 0 relative, input/output offsets will be an odd number. # For levels use 0 relative for both (pesa may be labeled 1 relative) # NOTE! Pesa serial: common RS232,9600,8,2,N,H # NOTE! Pesa serial cable needs the DSR tied to true # and RTS and CTS lines on many models # NOTE! Pesa level count will controll how many levels are sent out # the serial port. If this value is configured for 0, the mxlator # will use the number of levels reported on the first status request. # ENABLED: @FALSE [GVNMN_BUS_DATA_START] #NOTE! Up to 6 gvnmn bus control routers can be defined. Simply duplicate the GVNMN_BUS_DATA_START section 6 times # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # # # # ENABLED: @TRUE or FALSE # IP_ONE: @ # IP_TWO: @ # MX_GVNMN_MAPPING: @,,,,, # USI_SOURCE: @ # # ENABLED: @FALSE IP_ONE: @192.168.005.231 IP_TWO: @192.168.005.232 MX_GVNMN_MAPPING: @0, 0, 0, 250, 0, 0 USI_SOURCE: @MX [GVNSN_BUS_DATA_START] #NOTE! Up to 6 gvnsn bus control routers can be defined. Simply duplicate the GVNSN_BUS_DATA_START section 6 times # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # # # # ENABLED: @TRUE or FALSE # PORT: @ # LEVEL_4_ACK: @ default is TRUE # TIME_OUT: @<# of seconds with no messages before disconnecting, 0 = disable> default is 0 # MX_GVNSN_MAPPING: @,,,,, # USI_SOURCE: @ # # ENABLED: @FALSE LEVEL_4_ACK: @TRUE PORT: @12345 TIME_OUT: @0 USI_SOURCE: @MX [HCPM_BUS_DATA_START] #NOTE! Up to 6 hcpm bus control routers can be defined. Simply duplicate the HCPM_BUS_DATA_START section 6 times # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # # # # ENABLED: @TRUE or FALSE # IP_ONE: @ # IP_TWO: @ # IP_PORT: @ # ACK_WARN_TIME: @ # ACK_CLOSE_TIME: @ # MX_HCPM_MAPPING: @,,,,, # USI_SOURCE: @ # # ENABLED: @FALSE [LAWONM_BUS_DATA_START] #NOTE! Up to 6 Lawo netwok master bus control routers can be defined. Simply duplicate the LWONM_BUS_DATA_START section 6 times # the following fields are REQUIRED # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # # # # ENABLED: @TRUE or FALSE # IP_ONE: @ # IP_TWO: @ # IP_PORT: @ # MAPPING_TABLE: @ # DATA_REFRESH_TIME: @ # MX_LWONM_MAPPING: @,,,, # USI_SOURCE: @ # # ENABLED: @FALSE [LOGGING_DATA_START] # the format for this section is a FIELD LABEL followed by FIELD DATA # the FIELD LABEL must have a ':' as the last character # the FIELD DATA must start with a '@' char and be no longer than 20 characters # # SERVER_NAME: @ # LOGGING_SNIFFER_ENABLED: @TRUE or FALSE # LOG_COMMAND: @ # SERVER_NAME: @USI_SYSLOG01 LOGGING_SNIFFER_ENABLED: @FALSE [END_CONFIG_FILE]