############################################################################################################ KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# [VERSION:] 2.4.5 version 09-23-2011 2.4.5 11:00 AM 09/23/2011 1.ENH: In the Panels tab, replace Fast flag with connection type, which is more useful info for the customer. ############################################################################################################ KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 08-29-2011 2.4.4 11:00 AM 08/29/2011 1.BUG: XP info for old chassis, only sends info for the one xp that is active, so we used to clear the data used to display any data for the inactive xp, but we still need to show if that xp is installed so, we changed it to show that info. ############################################################################################################ KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 08-03-2011 2.4.4 9:30 AM 08/03/2011 1.ENH: Added list of new cards that RMAN needs to support for the series 2 TDM audio applications.The leading ‘12’ is not included in the data that comes back from RMAN. so we modified that list to change all of them to just the last 4 digits? IE, the 121292 becomes 1292. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 08-02-2011 2.4.3 03:00 PM 08/02/2011 1.ENH: Added list of new cards that RMAN needs to support for the series 2 TDM audio applications. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 07-11-2011 2.4.3 04:00 PM 07/11/2011 1.BUG: On the SC4 info tab, when the SC4 is not there, show empty all the columns in the tables od details. (slot location, active and partner board state were showing after the controller was down) FIXED. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 07-05-2011 2.4.3 11:30 AM 07/05/2011 1.BUG: On the SC4 info tab, the partner board states are : ready=green, not ready=yellow and offline=red (instead of gray) SHOW_SC4_ALARM_REDUN, and in the display chassis image, if the board partner is installed but boardpartnerstatus is offline= show red, installed but not ready= show yellow, other wise show green. Partner board | Partner board status | Ignore brd status --------------------------------------------------------------------- Not installed (gray) N/A (gray) 0, 1 installed (green) Ready(green) 0 Not Ready (yellow) Offline (red) installed (green) Ready (green) 1 ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 06-30-2011 2.4.3 2:30 PM 06/30/2011 1.BUG: On the SC4 info tab, the partner board states are : ready=green, not ready=yellow and offline=red (instead of gray) ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 06-16-2011 2.4.3 2:30 PM 06/16/2011 1.BUG: Calculating the position in the chassis table of a UT400 DATA works different than the other chassis types. It uses input/ouput in the formula backwards.FIXED ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 06-14-2011 2.4.3 4:00 PM 06/14/2011 1.ENH: Define MXLATOR chassis as Input/Output type, so it won't show as unknown anymore. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 06-09-2011 2.4.3 11:00 AM 02/23/2011 1.ENH: If a panel or a chassis is not a recognized type, display them as "Unknown" instead of blank or to not displaying them at all. 2.ENH: If a chassis is of an Unknown type, use the default offset size of 8, to calculate position in the display that won't clash with other types. 3.ENH: Added new chassis type UT400 Data. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 02-23-2011 2.4.2 11:00 AM 02/23/2011 1. BUG: when the communications went down, the tab status color wasn't being update. FIXED. 2. The Graphview Update gui process was not being called from inside the thread, which caused a deadlock on the main app, which caused the app to freeze and hang. This use to happen when the communications went up and down repeatedly.FIXED. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 02-21-2011 2.4.2 11:00 AM 02/21/2011 1. BUG: when saving and displaying Crosspoint data, if the chassy type is UT400_528,UT400_XL_BOTTOM, UT400_XL_TOP, UT400_DAV_144_S2, or UT400_DAV_288_S2 then check if the xpoint is installed to show data if not, then check if the xpoint is active to save the data. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 02-18-2011 2.4.2 03:00 PM 02/18/2011 1. BUG: The Display sc4 image option showed different crosspoints states when call from the sc4 or the crosspoint line. FIXED by using same function in both of them. 2. BUG: Problem with the state's color of the crosspoints. New rule implemented: Installed Active Color 0 0 Blue 0 1 Red 1 0 Yellow 1 1 Green 3. ENH: Added a list of cards that will be added to the system over the next several months – ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 02-17-2011 2.4.2 03:00 PM 02/17/2011 1. BUG: The alarmSummary thread was requesting sc4 log info and it shouldn't.Fixed by adding a command que to the thread that manages the updates from the alarm responses. 2. BUG: When the sc4 is down the Hardware log and the Alarm Summary button in the toolbar didn't reset the state (change color to gray) FIXED. 3. BUG: Some updates in the SC4 tab inside the hardware info tab didn't update the SC4 tab state (color) FIXED. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 02-16-2011 2.4.2 05:00 PM 02/16/2011 1. BUG: When the app starts and the user selects the Device Config tab, the src table was apppearing blank, it wasn't updating the data. FIXED by calling updatetableview after a change in the data. 2. Problem saving a connnection when the combo list was empty. Fixed. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 02-15-2011 2.4.2 04:00 PM 02/15/2011 1. BUG: When the user selects Display image in a particular tab, then closes the display image window, goes to another tab then comes back to the previous tab the Display image window reappears. FIXED by checking on the updateselection function if the displayImage dialog is visible before doing anything. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 02-11-2011 2.4.2 04:00 PM 02/11/2011 1. BUG: Add the init of the app, if the Connection list=Null it showed an error. Just needed a check for null case.FIXED 2. BUG: When the list of src/dest was big, it took a long time to load the graphical Status tab (specifically the update trees method). It was caused by the treesatusview not being a thread. FIXED. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 02-01-2011 2.4.1 10:00 AM 02/01/2011 1. BUG: In the hardware info tab, Under sc4 sub tab, the double click to display the sc4 image didnt work for sc4's with no power supply info.FIXED ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 01-31-2011 2.4 04:00 PM 01/31/2011 1. BUG: In the hardware info tab, the double click on a physical alarm column should display an image only if that field is bold.(i.e:UT_400_DA_32) Change the name of the the Graphical View tab to Router View tab. The tab state for the hardware info was shifted one position due to adding of the new router view tab. FIXED ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 01-26-2011 2.4 09:00 AM 01/26/2011 1. ENH: In the New Graphical View tab, When the user double clicks on the sc4, it will be selected in its hardware info tab and the Show me Option that brings the sc4 display image will be selected as well, so the user can see very quickly more details about the sc4. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 01-24-2011 2.4 11:00 AM 01/24/2011 1. ENH: New Graphical View tab, which shows a graphical summary of all chassis connected to the system's SC4 controller, organized by levels. Each icon will show the state of the chassis, green=OK, red=Error and yellow= warning to give the user a quick view into the state of the chassis in the system. When the user clicks on a chassis, a detail chassis table will be shown on the lower part of the graphical view screen. When the user double clicks on a chassis, that chassis will be selected in its hardware info tab and the Show me Option that brings the chassis display image will be selected as well, so the user can see very quick more details on the selected chassis. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 01-13-2011 2.4 10:00 AM 01/13/2011 1. ENH: In the SC4 info tab, inside the message, we added a new options field, which is now used to signal the app if an sc4 has power supplies data and partner board status data available. The GUI will display only the data provided. (sc4 400 dont have any power supply info). We could add other options to the code using this field. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 01-12-2011 2.4 2:00 PM 01/12/2011 1. ENH: In the tielines tab: Remember the current tieline selection. When the tielines table needs to be updated, after that the app will reselect the last row selected by the user. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 11-11-2010 2.3.2 11:00 AM 11/11/2010 1. ENH: New checkbox Menu option in the Config Menu: "Enable Acknowledge in Hw. Alarms Summ." This menu enable/disables the acknowledge button on the Hardware alarms summary dialog. The option is saved in the ini file so it remembers the user last selection. 2. ENH: Make all the toolbar buttons in the Hardware log, event log, and hardware alarm summary logs consistent, Print, Acknowledge and Clear. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 10-01-2010 2.3.1 11:00 AM 10/01/2010 1. BUG: Problem loading an image file (it had the wrong extension .gif instead of .GIF). FIXED ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 09-09-2010 2.3.1 03:00 PM 09/09/2010 1. ENH: In the chassis Table (hardware info tab) the number under chassis is the position of the chassis not its id, so The column name has been changed to "Ch. Pos" to avoid confusion. 2. ENH: In The active hardware alarms summary, the ID is the chassis ID, so in order to avoid confusion the column ID has been renamed to "Chassis ID" and a new column has been added to the summary "Chassis Pos" to help the user id the chassis better. 3. ENH: Move the dialog "hardware log", to a position located under the mouse cursor. If we don't do this there is a risk that the user clicks the "clear log" button by mistake, because in some cases when the dialog appears the mouse cursor is over the "Clear log" button. 4. ENH: The icons for the "Hardware log" and "Active Hardware alarm Summary" has been changed to other icons that help the user understand what the buttons are. 5. BUG: In the Summary of all chassis with errors, the lines were not showing selected. FIXED ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 09-03-2010 2.3.1 04:00 PM 09/03/2010 1. ENH: Added a new option in the main toolbar: View a Summary of all chassis with errors in them. it has a printing and acknowledge function as the log hardware alarm. If the user double clicks or right click on a chassis in this dialog, it will Open the right tab under the hardware info tab, so the user can see in detail what's going on with that chassis. The icon in the tool bar can be in 3 states: red: something has changed in the summary, yellow: there are still chassis in the summary but the user has acknowledged them (it will become red if something new happens) and gray: if there are no chassis in the summary. 2. ENH: When a chassis status is error or warning, all the cells of the row corresponding to that chassis will show the error or warning icon. This is to make it easier to see it if the user has a smaller screen. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 08-30-2010 2.3 12:10 PM 08/30/2010 1. BUG: The refresh hardware info button wasn't working for the SC4 tab. Now it Clears the tab and ask for the sc4 info to update the display. FIXED. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 08-26-2010 2.2 09:30 AM 08/26/2010 1. Add a acknowledge button in the log hardware alarms, that won't clear the log but it will clear the flag that signals new alarms have arrived, so the user can still see the old alarms but no the yellow status button on the log button. When another alarm comes in, the button will become yellow again, until the user acknowledges or clears it. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 08-25-2010 2.2 01:00 PM 08/25/2010 1. The sense of the LED is not an error/non error. It's a yes / no status(in the sc4 info tab) READY(s) PARTNER STATE Partner board not installed OFF YELLOW partner installed but not ready YELLOW GREEN partner installed and ready GREEN GREEN 2. Add Printing to the event and hardware alarm logs. 3. Show redundant rectangle when the user clicks to see the display chassis image in the sc4 tab ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 08-24-2010 2.2 01:00 PM 08/24/2010 1. When an alarm was issued from the sc4, the sc4 info tab wasn't being update (beacuse it was not being told to update the gui) FIXED 2. Add sc4 name to the log alarm status for alarmas different than LOS (chassis alarms not sc4 ones) 3. When a power supply is not installed, in the alarm log, it will receive the bit 7 set. Show not installed instead of all alarmas set for the one that is not installed. 4. Change the version from the ancient 2.1 to 2.2. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 08-23-2010 11:00 AM 08/23/2010 1. When an alarm was issued from the sc4, the sc4 info tab wasn't being update (beacuse it was tie with the update lists of the chassis alarm) FIXED 2. Added more details for the alarms: fan, power supply and temp. This is to make the log hardware alarms more informative. 3. Every time a new event is added to our hardware log event, change the color of the JButton in the main toolbar to let the user now that a new alarm has been logged. It will back to normal when all the logged events are cleared. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 08-20-2010 11:00 AM 08/20/2010 1. Get rid of the alarm status and alarm log, and substitute them with a single sc4 alarm log. So now we get all the events log and all hardware alarm events. Created it in a separate window. The user can acknowledge all alarms (which clear them all out) 2. Added Print button to the toolbar (only available when the hardware info tab is selected. 3. Error parsing the power supplies alarm in the sc4 info panel FIXED. Had the wrong numbers to and with the value. To-Do List 1. XL router extra info missing (4xp, monitor, fan, etc) 2. sometimes one of the fans in the show chassis option when it has an error shows blue instead of red(showed by mr roger on 11-13-09) 3. finish to calculate the correct position of the nodes in the graph (in recursive function) ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 08-10-2010 11:00 AM 08/10/2010 1. Add new tab inside HardwareInfo tab. The new tab called "SC4" has all the SC4 hardware info. It behaves as the rest of the level tabs, supporting functionalities as print, export data, see images, etc. Added the new parsing message to the protocol, it uses the same message misc data, but with a different type, to be able to parse depending on the type. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 08-03-2010 11:00 AM 08/03/2010 1. Change the color of the hardware info tab depending on the state of all the level tabs inside of it. ############################################################################################################ KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 08-02-2010 04:00 PM 08/02/2010 1. add support for new chassis: UT400_528_144 , UT400_528_288 (showing ext power supplies, xpoints and boards) the external power supply bit is the bit 80 (ps5) for xl top. bottom, 528 and these new types. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 07-22-2010 04:00 PM 07/22/2010 1. add new board descriptions for part # 1230-2 "UT4 S2 3G OUT HIGH SWING" ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 07-21-2010 11:00 AM 07/21/2010 1. Changed the 288R digital audio column name from �Power Supply External� to �PS Ext / Ref�. (only in the audio not the video). ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 07-20-2010 12:02 PM 07/20/2010 1. add new board descriptions for part # 1280 and 1281 ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 07-15-2010 04:00 PM 07/15/2010 (version went out to NCP truck) 1. Change the images of the ut400 144 redundant and non redundant, removing the last 4 boards. 2. Change the way the chassis status error gets set. instead of checking if the alarm type is!=-1, and the alarmtype with the smpte bit, if it is set, then is truly an error, otherwise is ok. 3. When the user open the display chassisimage dlg then closes it, opens another tab and then go back to the previous tab the display chassisimage dlg reappeared. FIXED by clearing the selection after the showchassisdialog image is closed. 4. Change some board descriptions to be more descriptive (changed in boardEntry) Changes by Mr Jeff Levie. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 07-14-2010 1:00 PM 07/14/2010 1. When the sc4 went down and it took 4 mins or more to reconnect and the displaychassisimage dialog was up when the sc4 reconnected the gui hung. Fixed by closing the displaychassisimage dialog when the communications go down. 2. Bug with the rendering of the first row of evry table, that looked like the row ) didn't get render correctly Fix by changing the preparerenderer function without overriding the setcellrenderer function. 3. When showing board info in displaychassis image dialog, let the user sort the columns. 4. Change some board descriptions to be more descriptive (change in boardEntry) ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 07-12-2010 3:30 PM 07/12/2010 1. Show Signal Presence in the bnc info table, when the user select the option show images from board. Checks the signal presence 2 bytes of info and finds out if the signal is present or not for each bnc. Show all BNC's, not only the ones with names. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 07-02-2010 1:00 PM 07/02/2010 1. Problem when down sizing the hardware info tab. (the scrollbars of the boards don't scroll when the window is resized) partially Fixed by adding a parent.repaint() when the scrollbar gets an event. It's partially fixed beacues the arrows up and down in the scrollbar work but the drag with the mouse on the scrollbar doesn't work. (weird beacuse it goes to the same event listener from the scrollbar) ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 06-30-2010 9:00 AM 06/30/2010 1. Image rear and fron for devices 528, xltop and xl bottom were too big. Fixed by replacing images for smaller ones (350 x504) 2. Added new types of devices that have the reference bit. DA_144, DA_288_INP, DA_64, DA_144_REDUN, DA_32 and DA_288_REDUN. 3. Problem when downsizing the displaychassisimage dialog. teh scrollbars didn't show the whole window. FIXED ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 06-17-2010 2:00 PM 06/17/2010 1. Export the hardware info (by selected chassis) to a .csv file. The user can change the location of the file 2. When the chassis has 2 power supplies. if one of them is marked as an error, check smpte and if it is not an error, the set the ps to -1 (not installed) ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 06-15-2010 4:00 PM 06/15/2010 1. Fix error that displayed the wrong xpoints. one crosspoint dissapeared. Treat the 51, 52 and 53 chassis type different than the rest (chassismiscdata) 2. Fix Panels view, now the image is scale maintaining the same ratio (applying the same logic used in printing hwinfo) ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 06-14-2010 3:40 PM 06/14/2010 1. PROTOCOL CHANGE. 528, XL BOTTOM and XLTOP, change some alarm bits ( instead of two ps, has just one general error external power supply, instead of having a xp ps error, it has now a xp error) change column names as well 2. The showChassis fucntion now shows all the info from the chassis( instead of only displaying the exception) 3. Print hardware info by chassis (chassis info, xp, alarms and boards) ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 06-11-2010 4:00 PM 06/11/2010 1. Added list of names for the new boards in the xl (in boardEntry file) 2. Print hardware info by chassis (chassis info, xp, alarms and boards) (still needs some work) ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 06-09-2010 8:30 AM 06/09/2010 1. Change protocol so we can save the right crosspoints info.Saved in an array of size 4 (max) 2. Print hardware info by chassis (chassis info, xp, alarms and boards) (still needs some work) 3. When the part No and SubPart No don't match a defined board name, print out "Unknown" instead of "" 4. When an alarm has been cleared but hasn't been acknowledged, set the icon to a yellow led (not red as it was before) Clear and ack = green, others red (alarmStatus file) ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 06-03-2010 (Before protocol changes for xpoints) 3:30 PM 06/03/2010 1. Add a new column on physical alarm info table called "Reference" for only the chassis Types: 4A and 47 on the hardware info tab. It uses the same high bit as the power supply 5 on the other chassis types. 2. In the Display Chassis Image Dialog, modify the BNC lists to support more than 8 (like 12 for the 528, XL BOttom and XL Top). Fixed by making the size of the array variable depending on the BNC start and stop values. 3. Make the Display Chassis Image dialog scrollable so it can fit in a smaller screen. Fixed by adding all the panels to a main scrollpane.() ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 04-21-2010 9:00 AM 04/21/2010 1. BUG: Hardware info tab bug when the user shrinks the app and the scrollbars appeared the double click and popup menu didnt work, beacuse the coordinates recieved by the mouse click needed to be translated to the viewport world.Fixed by adding the scroll position to the e.getpoint ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 04-13-20010 1:00 PM 04/13/2010 1. BUG: Hardware info tab didn't have a scrollpane. Added new scrollpane so in theory should work on smaller screens. 2. BUG: all the tabs of the mainview had a limit in their scrollbars that the user could pass while shrinking the main app window. Now we added a minimum size to the main tabs as well as the minimum size of the app per se. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 04-12-20010 3:00 PM 04/12/2010 1. ENH: Allow the user to delete the connections saved by the connection dialog. 2. ENH: in the Panel image view, the images has been modified to be a bit smaller so the image won't get to big or distorsioned. (needs a bit more work) ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 04-09-20010 3:00 PM 04/09/2010 1. ENH: Allow the user to select a columm in the tabular status table and device config table, then press a key to found the next available device name that begins with the input. select that row and make it visible (to make searching for names a bit easier) 2. ENH: Add Panel image view. In the panels tab, when the user clicks on a panel in the panel table, the picture associated with the panel model is shown below. it's a dual panewl like tielines 3. ENH: The user can now save connections in the ini file. in the connect dialog, you can now select an already saved connection to connect to. The program remembers that last one. 4. BUG: When a panel got added or disconnected from the sc4 the panels table wasn't updating properly (FIXED) 5. The locks and protects shown on the graphical status view, were position based. This caused a problem when the device list didn't match the display. Now they are searched and shown by device name independently of the position in the table. (FIXED) ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 04-07-20010 10:00 AM 04/07/2010 1. ENH: Allow the user to select a columm in the tabular status table and device config table, then press a key to found the next available device name that begins with the input. select that row and make it visible (to make searching for names a bit easier) ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 04-06-20010 12:00 AM 04/06/2010 1. ENH: Add chassis ID to the chassis details table. 2. ENH: HIghlight the row selection in the device tables (tabular status and device config) 3. BUG: lock status was arriving before the devices info, so we send the request for lock status after all the input and output devices has been recieved. closed synchronization. 4. ENH: Add panel tab, that shows all the panels in the controller. the user can right click one of them to display the Locate ON/OFF menu. Locates the panel in the rack by making it flash. 5. ENH: Now in the tabular status, the user can see not only the panel id of the panel that locked or protected, but the panel name also, for more info. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 04-01-20010 11:00 AM 04/01/2010 1. when all the boards in a chassis are inactive, show the board num in the table as 0, and colored red, as if it was an error. BOardnum=numbre of row and color white, just empty board now. (FIXED) ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 03-29-20010 9:00 AM 03/29/2010 1. make the ps3, ps4,ps5 bold and underlined in the chassisalarm table. (FIXED) ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 03-26-20010 11:00 AM 03/26/2010 1. Added 3 more power supplies to the ut400 288 redundant, change alarm table in hardware info to have as many power supplies columns as it needs, depending on the chassis type. Img modified to show the power supplies. 2. AlarmManager causes problems with the reconnect, after an sc4 is reset. Make the alarm manager runnable and add a thread inside of it to loop thru all functions. (FIXED) ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 03-24-20010 02:00 PM 03/24/2010 1. Finish tieline tab functionality (ask for updates periodically) new command that asks for changes in tielines added. (FIXED) 2. BUG: error calculating the usage of a tieline. FIXED ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 03-22-20010 02:00 PM 03/22/2010 1. rMan consumed 25% of CPU. (it went from 1% to 25%) due to the threadmanagewr not having a sleep. Sleep of 1/2 second added to the alarm manager. (FIXED) ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 03-19-20010 06:00 PM 03/19/2010 1. added a threadmanager that controls the sounds of the alarms config by the user. it has 2 threads: sound and display. the user gets to select if it clear all or hjust the curretly playing alarm. (to be tested) ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 03-10-20010 04:00 PM 03/10/2010 1.Added new option to Config menu: config alarm sounds. This dialog allows the user to select which alarms (saved in the settings file) are going to have a sound associated with them. lets the user select what sound file to play when that alarm occurs, how many time is going to be repeated and with how much delay in between. 2.Tab "SC4" has been eleiminated from the hardware info tabs. this was included just as a test, no need to have it there anymore. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 03-04-20010 04:00 PM 03/04/2010 1. Make the tabular status table,device config src and dest table sortable (still working on the tree sorting of the graphical view. 2. Show state of the pools in the tielines table. Green indicate that there are still tielines available for use red indicates that all the tielines in the pool has been used and yellow means thatthe number of tielines used exceeded the alarm threshold of that pool. 3. Added a tooltip to the pool column in the tielines table to show the pool stats (capacity, alarm and usage) ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 03-03-20010 04:00 PM 03/03/2010 1. Fix zize of the path panel to grow and shrink depending on the path size 2. double click on a node in the tieline graph and go to that path if the node is a tieline. 3. Add icons to the nodes 3. made the nodes resized depending on th icon + text size. 4. just expand the dests that are tielines (in the path graph) not the sources. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 02-26-20010 01:00 PM 02/26/2010 1. Fix sorting tielines 2. double click on a node in the tieline graph and expand the path if the node is a tieline. 3. made the graph panel no editable, no resizable and don't allow it to disconnet any edges. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 02-22-20010 04:00 PM 02/22/2010 1.Remove labels from tieline path graph. 2. Fix tieline dests issue. We can have dests with same id but with different type. 3. Fix Reconnecting isue 4. Add Clear Tieline fucntion. Right click on a tieline with dest defined and a take for each dest will be sent to clear it. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 02-19-20010 09:00 PM 02/19/2010 1.ENH add tieline tab, that shows all tielines set in the systew, with a summary and graphical view (not finish yet) 2.BUG add images for chassis type DA 144 REDUN. (works as the DV 144 REDUND) 3.bug IN PARSELEVELINFO() we were not storing the first level info because the parsing was wrong. the array of chars was size 12 and it was supposed to be 11 (FIXED) ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 01-25-20010 03:00 PM 01/25/2010 1. Display/Set and Clear Locks and protects in the graphical status tab. Right click to show menu. The icons next to the output device are: Clear(output icon), Lock (blue padlock), protect (yellow shield) and protect/lock (yellow padlock). The lock icon will appear if one or more levels in the output are locked. The protect icon will appear if one or more levels in the output are protected. The protect/lock icon will appear if one or more levels in the output are both locked nad protected. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 01-22-20010 03:00 PM 01/22/2010 1. Display/Set and Clear Locks and protects in the tabular status tab.Hovering over a level it will show which panel has it protected or lock. 2. The state of the boards, xpoints, alarms etc is displayed with the same color as the rectangle that shows it in the image (hardware info tab) to make it consistent and easier to the user to know what the colors represent. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 11-03-2009a 02:00 PM 11/03/2009 1.new inside pictures for the new chassis (528,XL(top and bottom) added to the code. showing boards, ok. 2. the user now can show the fan info in the displayimage dlg. ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 10-22-2009a 01:00 PM 10/22/2009 To-Do List 1. Changed chassistype for the Ut 400 528 and XL ids. 2. Still need to get the new inside pictures for the new chassis (528,XL) ############################################################################################################# KEY BUG < Guess ;-) > ENH Enhancement ANMY Anomaly ############################################################################################################# version 8-05-2009a 10:00 AM 08/05/2009 To-Do List 1. fix repaint problem when resizing the boardtables(Solved by fixing layout and removing scrollpane) ############################################################################################################# version 7-27-2009a 01:00 PM 7/27/2009 1. Add tooltip to last column of xpoint table to show that user can right click it also (DONE) ############################################################################################################# version 7-24-2009a 10:00 AM 7/24/2009 1. Clear REctangles from display chassis image when the selection changes (DONE) ############################################################################################################# version 7-23-2009a 01:00 PM 7/23/2009 1. Show error warning boards when display image from chassis(Done) 2. Show error in xpoints and power supply also (DONE) 3. fix repaint problem when resizing the boardtables 4. bold and underlined the cells that have pupup menus and doulbe click options.(DONE) 5. Replace the state in the info table for Type ( input, output, i/o, xpoint) (DONE) 6. Replace missing in the state from board for (Configured but not installed), do the same with new (DONE) 7. Refresh issue with the display chassis image when it comes from Chassis table.(DONE) ############################################################################################################# version 7-22-2009a 11:00 AM 7/22/2009 1. Show error warning boards when display image from chassis(Done) ############################################################################################################# version 7-21-2009a 4:00 PM 7/21/2009 1. Tooltips to show mouse options (DONE) 2. Show Xpoint info when displaying image from xpoint (DONE) 3. fix coordinates for new images provided by mr Scott.(DONE) ############################################################################################################# version 6-4-2009a 10:15 AM 6/4/2009 1. BUG When > 4 chassis the Chassis alarm log messages (5 seconds requests) are sent in > 1 (FIXED) message. rMan appears to be ignoring all after the first one. - It should keep processing until it sees the END OF TABLE command from the SC4 before it calls analyze (FIXED) 2. BUG When a chassis is removed from the SC4 the chassis details/alarms/crosspoints/boards sections don't clear out. 3. BUG Chassis Alarms PS1 and PS2 are using the same bit to display the error. Meaning (FIXED) - PS1 ERROR PS1 & PS2 show error - PS2 ERROR NO errors displayed 4. BUG Chassis Table Type0 field for router type 45 shows invalid where it should show I/O or Input/Output (FIXED) 5. ENH Need to spruce up the Cross Points Section - PN should be displayed as hex (FIXED) - Sub (OK) - Rev should be displayed as hex (already is) - SN ?? - SW is really 2 BYTES (hex) HI/LOW 0x0214 and should be displayed as 2.14 not 532.0 - FW is really 2 bytes (ascii) HI/LOW 0x3231 should be displayed as 2.1 not 12849.0 - installed / active needs udpate 6. BUG When a chassis goes offline............(FIXED) - it disappears frmo the Chassis Table entry and should not. - Chassis Physical alarms all show as GREEN and Chassis lost should be RED - creates exceptions when processing the message (divide by 0) 7. BUG When a NON-CONFIGURED chassis is removed the chassis table line goes away but the remaining data below is not cleared. - The line is chassis table is blanked to a white background link it's selected????? 8. ANMY When rMan updates the display after a chassis change the task bar @ the bottom becomes active??? 9. BUG When use CNTL-PGUP/PGDWN to change tabs nothing gets updated (FIXED)